Gerling Laboratories Repair Facility for Motor Controllers
Home Repair Program Return Form ?Repairable? Test & Reinstallation SCR Control PWM Control SMPS Control Customer Comments Controller History Motor Test

Repair Program

Background - Gerling Laboratories is mostly about John Gerling, a retired electrical engineer.  Making a long story short, one of John's hobby is using a mini-mill and lathe.  The controller for his mill failed and a replacement was not immediately available.  John took it as a personal challenge to repair his, did so and in doing so learned a great deal about SIEG controllers.  One thing led to another and with the help and encouragement of several in the field and the unfortunate demise of Uncle Rabid, a major repairer, he decided to turn his knowledge and capability into a business.

Facility  - The facility consists of two stations.  The picture at the left is of the test console custom designed and built specifically for the SIEG line of controllers.  It is used to locate the problems in defective units, test the repaired controller and make the on-board adjustments.  The second is a repair station using state-of-the-art equipment  from Aoyue to remove and replace through-hole and surface mounted components as required. 

Program - A returned controller will fall into one of these categories: (note that the following applies to any controller listed on the Home page)

  • (1) It is defective and cannot repaired.  An email report will be made to the owner.  It will returned for a charge of $8.00 for shipping costs ($10 if it includes a control box) or scrapped with the owners permission with no charge. (see     ?Repairable? page for discussion)

(2) It has defective components.  These components will be replaced, the on-board settings will be made  and it will be tested and returned with a test report for a charge of $50.00 plus the return cost.  There are no extra charges for the components replaced.  If an upgrade is available for that model, it will be installed for no extra charge.

All returned items, foreign and domestic, will be shipped via USPS Priority mail with a tracking number.  An email with the tracking number will be sent on the day it is shipped.

Test Report and Reinstallation Instructions: Each board returned after being repaired will come with a final test report and reinstallation instructions.  These instructions give diagnostic tests to each part of the control unit to make sure any problems that might exist are resolved.  In addition, a properly rated fuse will be included.  We have found that over fusing is a serious problem which can cause traces on the PC board to be damaged.

Sample test and reinstallation instructions can be seen HERE

The above charges are for US customers.  I accept controllers to be repaired from other countries. The charge is $50.00 plus the cost to return the item

Warranty - The warranty given to a repaired unit is limited as follows:

I give a repaired controller a rigorous final test including 30 minutes of continuous operation at full power and have a firm belief that it will perform properly in a trouble free environment.  I provide test instructions to help find fault conditions in the operating installation.  I have no control over the operating conditions and cannot give an operating time warranty after reinstallation.  Should there be a problem after reinstallation, I will do everything possible to help solve it including a one time retest and repair (if possible).  In such a case, the customer is responsible for two way shipping and direct cost of any repair parts that might be required.  A successful rerepair is not guaranteed. 

Return Procedures - To send a unit to Gerling Laboratories for analysis and/or repair, download the return form HERE, fill it out, enclose it with the controller and mail to the indicated address.

Contact - To email us please click HERE.  We try to respond within 24 hours.